Wavefront / QWLSI

A Powerful Alternative Overcoming Shack-Hartmann and Classical Interferometer Limitations

QWLSI: A Trusted 20+ Year Wavefront Sensing Technology

For over two decades, Quadriwave Lateral Shearing Interferometry (QWLSI) has been a proven and trusted wavefront sensing technology for high-end wavefront metrology and quantitative phase imaging. Industrialized by Phasics, this 20+ year industry-approved technology offers a powerful alternative to Shack-Hartmann based wavefront sensors and classical interferometers, such as the Fizeau and Twyman-Green.

Read more

The QWLSI Principle: Advanced Wavefront Sensing

QWLSI measures both phase and intensity with nanometric sensitivity and very high spatial resolution. Unlike a Shack-Hartmann wavefront sensor, which relies on a microlens array, our wavefront sensing technology utilizes a patented modified Hartmann mask approach.

 

Diffractive Grating: A smart diffractive grating replicates the incident beam into four identical waves.

Interferogram Generation: These waves overlap and interfere after a few millimeters of propagation to create a high-resolution interferogram on the detector.

Precise Encoding: Phase gradients are encoded in the interference fringe deformations, allowing the wavefront sensor to reconstruct the beam with extreme detail.

QWLSI Advanced Wavefront Sensing

Why QWLSI is the Leading Wavefront Sensor Alternative:

QWLSI Wavefront Sensor

Superior Dynamics: QWLSI based wavefront sensor allows for the direct measurement of highly diverging beams without the need for expensive relay lenses or Computer-Generated Holograms (CGH). Wavefront errors of several millimeters Peak-to-Valley are measurable with high precision. 

Vibration Immunity: Unlike Fizeau and Twyman-Green interferometers, QWLSI is a self-referenced system with no reference arm. This makes it compact, insensitive to environmental noise, and perfectly suited for production floors. 

Total Achromaticity: While a Shack-Hartmann wavefront sensor is limited by the chromaticity of its microlenses, and interferometer limited by the integrated light source, QWLSI is inherently achromatic across the entire spectral range of the detector. 

20+ Years of Trust: Used and trusted by the industry for over two decades, it is a reliable wavefront sensing technology for laser qualification, optics testing, and material inspection.

Comparing Wavefront Measurement Technologies

  CompactnessSamplingWavelength
dependency
Sensitivity
to vibrations
Dynamic
range
Cost
FIZEAU
IMAGE-FIZEAU
Bulky System
✓✓
Very high
✕✕
Limited by the laser source
Sensitive to environment
✕✕
Very limited – null testing with CGH
$$
PHASICS
QWLSI
IMAGE-PHASICS-QWLSI
Camera like device
High up to 852 × 720
Achromatic: only limited by the detector
Self referenced: not sensitive to vibrations
✓✓
Up to 500 µm PtV
$
SHACK
HARTMANN
IMAGE-SHACK-HARTMANN
Camera like device
Low
Limited by the chromatism of the microlenses
Not sensitive to vibrations
Limited
$

QWLSI vs. Fizeau & Twyman-Green: Accuracy Without the Bulk

Classical interferometers like the Fizeau or Twyman-Green are valued for high resolution but require a complex reference beam and a highly stable environment. These systems often lack flexibility regarding test wavelengths. QWLSI provides comparable precision in a robust, compact wavefront sensor format that does not require an external reference arm.

 

QWLSI vs. Shack-Hartmann: Resolution Without Compromise

The Shack-Hartmann wavefront sensor lacks the resolution required for complex beam analysis due to the fixed geometry of the microlens array. QWLSI overcomes this by using a diffractive grating that provides a dense measurement grid, ensuring no detail is lost.